WHC-N AC Contactor
|
|
|
|
Application
|
|
WHC-N series AC contactors are suitable for frequency 50/60Hz, rated insulationvoltage up to 1000V, rated operation current 9~150A under AC-3 duty. It is mainlyused for making and breaking electric circuits at a long distance & for frequentstrarting, stopping & controlling AC Motors. It is used in combination with thrmal relay to compose a magnetic motor starter. The products comply with IEC6047-4.
|
|
Standard Control Circuit Voltages
|
|
Volts
|
24
|
42
|
48
|
110
|
220
|
230
|
240
|
380
|
400
|
415
|
440
|
500
|
660
|
50Hz
|
B5
|
D5
|
E5
|
F5
|
M5
|
P5
|
U5
|
Q5
|
V5
|
N5
|
R5
|
S5
|
Y5
|
60Hz
|
B6
|
D6
|
E6
|
F6
|
M6
|
-
|
U6
|
Q6
|
-
|
-
|
R6
|
-
|
-
|
50/60Hz
|
B7
|
D7
|
E7
|
F7
|
M7
|
P7
|
U7
|
Q7
|
V7
|
N7
|
R7
|
-
|
-
|
|
|
Specificarions
|
|
Rated operational
currenr
|
Ie max AC-3 (Ue≤440V)
|
9A
|
12A
|
18A
|
25A
|
32A
|
Ie AC-1 (0≤60℃)
|
25A
|
|
32A
|
40A
|
32A
|
Number of poles
|
|
3
|
3 4
|
3
|
3 4
|
3
|
Rated operational
power in AC-3
|
220/240V
|
2.2KW
|
3KW
|
4KW
|
5.5KW
|
7.5KW
|
380/400V
|
4KW
|
5.5KW
|
7.5KW
|
11KW
|
15KW
|
415/440V
|
4KW
|
5.5KW
|
9KW
|
11KW
|
15KW
|
500V
|
5.5KW
|
7.5KW
|
10KW
|
15KW
|
18.5KW
|
660/690V
|
5.5KW
|
7.5KW
|
10KW
|
15KW
|
18.5KW
|
1000V
|
-
|
-
|
-
|
-
|
-
|
Auxiliary contaces
|
range comprising up to 4 N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2 N/O or N/C protecred
contacts and 2 screen continuty terminals
|
Compatible manualauto
thermal
overload relays
|
Class 10A
|
0.10...10A
|
0.10...13A
|
0.10...18A
|
0.10...32A
|
0.10...38A
|
Class 20
|
2.5...10A
|
2.5...13A
|
2.5...18A
|
2.5...32A
|
-
|
Suppressor modules
(d.c.and low consumption
contactors have built-in
suppression as standard)
|
Varistor
|
●
|
● ●
|
●
|
● ●
|
●
|
Diode
|
-
|
- ●
|
-
|
- ●
|
-
|
RC circuit
|
●
|
● ●
|
●
|
● ●
|
●
|
Bidirectional peak limiting diode
|
●
|
● ●
|
●
|
● ●
|
●
|
Interfaces
|
Realy
|
●
|
● ●
|
●
|
● ●
|
●
|
Relay + voerride function
|
●
|
● ●
|
●
|
● ●
|
●
|
Solid state
|
●
|
● ●
|
●
|
● ●
|
●
|
Contactor type
references
|
~ or- 3P
|
WHC-N09
|
WHC-N12
|
WHC-N18
|
WHC-N25
|
WHC-N32
|
~ 4-P
|
-
|
WHC-N12
|
-
|
WHC-N25
|
-
|
=4P
|
-
|
WHC-N12
|
-
|
WHC-N25
|
-
|
Reversing contactor
type references
|
~ 3P
|
WHC-N09
|
WHC-N12
|
WHC-N18
|
WHC-N25
|
WHC-N32
|
=3P
|
WHC-N09
|
WHC-N12
|
WHC-N18
|
WHC-N25
|
WHC-N32
|
~ 4P
|
-
|
WHC-N12
|
-
|
WHC-N25
|
-
|
=4P
|
-
|
WHC-N12
|
-
|
WHC-N25
|
-
|
|
|
|
|
38A
|
40A
|
12A
|
12A
|
12A
|
12A
|
12A
|
12A
|
|
60A
|
|
|
|
|
|
|
|
3 4
|
3 4
|
3 4
|
3 4
|
3 4
|
3 4
|
3 4
|
9KW
|
11KW
|
3KW
|
3KW
|
3KW
|
3KW
|
3KW
|
3KW
|
18.5KW
|
18.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
18.5KW
|
22KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
5.5KW
|
18.5KW
|
22KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
18.5KW
|
30KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
7.5KW
|
-
|
22KW
|
-
|
-
|
-
|
-
|
-
|
-
|
range comprising up to 4 N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up to 2 N/O or N/C protecred
contacts and 2 screen continuty terminals
|
0.10...38A
|
17...50A
|
17...70A
|
17...80A
|
17...104A
|
17...104A
|
60...150A
|
60...150A
|
|
17...40A
|
17...65A
|
17...70A
|
17...80A
|
|
60...150A
|
60...150A
|
●
|
● ●
|
●
|
● ●
|
● ●
|
●
|
● ●
|
-
|
-
|
● ●
|
●
|
● ●
|
● ●
|
●
|
- -
|
-
|
●
|
● ●
|
●
|
● ●
|
● ●
|
●
|
● ●
|
●
|
●
|
● ●
|
●
|
● ●
|
● ●
|
●
|
- -
|
-
|
●
|
● ●
|
● ●
|
● ●
|
● ●
|
●
|
● ●
|
●
|
●
|
● ●
|
● ●
|
● ●
|
● ●
|
●
|
● ●
|
●
|
●
|
● ●
|
● ●
|
● ●
|
● ●
|
●
|
● ●
|
-
|
WHC-38N
|
WHC-40N
|
WHC-150N
|
WHC-65N
|
WHC-80N
|
WHC-95N
|
WHC-115N
|
WHC-150N
|
-
|
WHC-40N
|
-
|
WHC-65N
|
WHC-80N
|
-
|
WHC-115N
|
-
|
-
|
WHC-40N
|
-
|
WHC-65N
|
WHC-80N
|
-
|
WHC-115N
|
-
|
WHC-38N
|
WHC-40N
|
WHC-150N
|
WHC-65N
|
WHC-80N
|
WHC2-D95
|
WHC-115N
|
WHC-150N
|
WHC-38N
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
WHC-40N
|
-
|
WHC-65N
|
WHC-80N
|
-
|
WHC-115N
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|